Coldture Xtreme Outdoor Cold Plunge - Manual

Download PDF

coldture Pro Plunge Xtreme User Manual

Cover page showing the Coldture Pro Plunge Xtreme user manual title with a woman in a cold plunge tub

Welcome to the Coldture Wellness Club

Clear your head.

Fuel your energy.

Push past limits.

The Pro Plunge Xtreme isn't just cold, it's built for the wild. Canada's first fully functional outdoor cold plunge, engineered to perform in temperatures as low as –30°C. Whether it's your backyard, cottage, or right beside your sauna, this plunge keeps up with every season. Step in and feel your stress drop, your focus sharpen, and your body fire into recovery mode.

Here's what the Pro Plunge Xtreme delivers:

Less soreness Cold therapy tightens blood vessels, easing sore muscles and reducing inflammation.

Faster recovery Bounce back quicker, ready for your next workout or simply the rest of your day.

Better circulation Boosts blood flow, supporting healing, energy, and overall performance.

Inflammation support May ease chronic inflammation and conditions like arthritis. (Check with your doctor if you have health concerns.)

Get in. Chill out. Come back stronger.

Coldture Pro Plunge Xtreme unit shown on a wooden deck with leaflet on the side

Contents

Important Information!

Please read these instructions carefully before using the appliance and retain them for future reference.

During transport, do not tilt the water chiller more than 45° in any direction.

Do not restrict or block the air inlet or exhaust air outlet of the unit.

Never use cleaning agents containing sand, soda, acid, or chloride, as these may damage surfaces.

Before opening the device, ensure that all circuits are isolated from the power supply.

Any work on the water chiller must only be performed by authorized and qualified after-sales service technicians.

Health & Safety Warnings for the User

Taking the plunge is a big step

Coldture Wellness declines all liability for damages arising for failure to observe the following directions.

Health disclaimer:

If you're unsure about whether this is for you then please check with your doctor before using your Pro Plunge Xtreme.

The Pro Plunge Xtreme is suitable for most people most of the time. However, we recommend taking a cautious approach and advise that people with reduced mobility, sensory, and/or cognitive abilities only use the Pro Plunge Xtreme if supervised and only if they have the knowledge necessary to use the equipment safely, as well as to understand the dangers arising from improper use.

Tolerance to cold water varies from person to person. We recommend being mindful of gradually building up the duration of use with your Pro Plunge Xtreme and being cautious when using it alone.

New to this?

It is quite dangerous to suddenly jump into cold water that's significantly cooler than what you're used to as it can cause a shock to the body. Therefore, enter the water slowly and keep your face, shoulders, and hands clear until your breathing is under control.

The cold-water shock response decreases with cold exposure experience and being mentally prepared.

A risk factor is hypothermia.

This occurs when you suffer a drop in core body temperature and can eventually lead to loss of consciousness and heart failure.

The amount of time you can spend in cold water without suffering from hypothermia is determined by the water temperature, your body size and shape, your level of cold adaptation and your experience, among other factors. Check with your doctor as relevant. Start with safe, short dips of 30 seconds to learn what your limits are. If you begin to feel uncomfortable or you start to shiver, listen to your body, get out and slowly warm up by walking around.

If you like, you can check the water temperature before entering the bath, to ensure that it is at a temperature that is suitable for your experience in cold exposure. The temperature of the water is displayed as default on the control panel.

Children must be supervised near your Pro Plunge Xtreme to make sure they do not play with the equipment and do not carry out operations to be performed by adults (cleaning cycles/maintenance). Always attach the cover when not in use. Children are not advised to use the Pro Plunge Xtreme.

Please check with your doctor as relevant.

Pregnant women should talk to a doctor first, low temperatures are not advised. Anybody under medical care, such as people with heart conditions, diabetes, high or low blood pressure or other health problems must not use your Pro Plunge Xtreme without first consulting their doctor. People with infectious diseases should not use your Pro Plunge Xtreme without first consulting their doctor.

Product Specifications

SpecificationDetails
ModelPro Plunge Xtreme
Dimensions (inches)85" x 41" x 30"
Electrical115V, 60Hz
Capacity1 person
Water Capacity113 gallons / 0.43 m³
Net Weight359 lbs / 163 kg
Overall Weight1492 lbs / 677 kg
Product image showing the Pro Plunge Xtreme ice bath with white interior and dark wooden exterior panels

Set-Up Instructions

Installation Instructions

Location and Space

Electrical Installation

Pre-Operation Checklist:

Heat Pump Controller

Operation Instructions

Pre-use Operations

1. Please connect power strictly according to the power data plate.

Electrical wiring diagram showing connections between compressor, controller, fans, and various components with input voltage AC110-120V 60Hz and max total load 12.6A

2. After connecting the load and checking it in detail, turn on the power and use it normally.

Control panel display showing temperature 23°C and mode indicators, with labeled buttons for TEMP-, TEMP+, mode switching, working mode selection, clock setting, timing setting, and power on/off

Display Illustrations

Circular display interface showing digital temperature reading, various mode icons, and control buttons

Heating mode

Cooling mode

Silent mode

Intelligent mode

Strong mode

Defrosting in progress

Wi-Fi successfully connected and permanently lit; flashing when not connected or during connection

Lock screen

Blinking when reporting a fault

Water pump on

Settings

Working Mode

Three displays showing transition from off to cooling to heating mode

1. Long press 3s to turn on.

2. Long press M 3s to switch between cooling and heating mode.

At the startup interface, press ⏲ to switch modes: silent, intelligent, and strong

Three displays showing silent, intelligent, and strong mode indicators

Clock Setting

Three displays showing clock setting sequence with hour and minute adjustment

1. Long press 3s .

2. Press "▼" or "▲" adjust the hour.

3. Press "▼" or "▲" adjust the minute. press "⏲" "confirm the value and return.

Timing Segments Control

The timing of the second and third segments is also switched through the SET. The DOWN and UP adjust the hours and minutes, and press SET to exit.

Digital thermostat display showing timing settings with temperature at 20.4°C and various timing indicators

1 Indicates that there is a timing

Timing on

Timing off

Cancel timing setting: When the set startup time and shutdown time are the same, the timing setting for the current time period is cancel.

Children Lock Protection Setting

Three sequential thermostat displays showing the process of enabling children lock protection

Long press SET and UP keys for 3s on the main interface. Children lock protection enable.

Long press SET and UP keys for 3s again. Children lock protection disable.

Wifi Setting

Download the App

Method 1: Search "Smart Life" in Apple App Store or Google App Store.

Method 2: Scan the QR code below, download and install "Smart Life" APP.

QR code for downloading Smart Life app

User registration

Click the icon "Smart Life" to start the software.

To use the "Smart Life" software for the first time, you need to register users: create a new account → enter a mobile phone number/email → enter a verification code, set a password → confirm

Two mobile app screenshots showing the registration process for Smart Life app

To use the "Smart Life" software for the first time, you need to register users: create a new account → enter a mobile phone number/email → enter a verification code, set a password → confirm

Two more mobile app screenshots showing Smart Life app setup with 'Turn on your smart life' screen and room selection interface

Two options to activate WiFi

Option 1: Quick flash mode

Option 2: Slow flash mode

Two thermostat displays showing WiFi flash modes with temperature displays and button instructions

Push "mode" and "arrow up" At the same time for 5 seconds.

Push "power button" and "arrow down" at the same time for 5 seconds.

User Registration

SMART mode

Three mobile app screenshots showing WiFi network connection setup, with WLAN network selection and device discovery

OPEN "WLAN"

Connect to the network

WiFi Reset and Connection Process

long press the WIFI reset button for 3 seconds, and then click "confirm that the indicator is flashing".

Two mobile app screenshots showing device addition process and WiFi password entry screen Three mobile app screenshots showing connection progress from 2% to 59% and final success screen

Operation

The device is bound successfully. Click "completed" to enter the operation page directly.

Mobile app interface showing water mode operation screen with temperature settings, fault information display, and control buttons

Error Codes

CodeFault Description
Er 03Water flow fault
Er 04Winter antifreeze
Er 05High pressure fault
Er 06Low pressure fault
Er 09Mainboard-wire control communication fault
Er 10Frequency conversion module communication fault
Er 12Exhaust high protection
Er 15Inlet water temperature fault
Er 16External coil temperature fault
Er 18Exhaust temperature fault
Er 19DC fan 1 fault
Er 20Frequency conversion module abnormal protection
Er 21Ambient temperature fault
Er 23Cooling water outlet temperature too low protection
Er 27Water outlet temperature fault
Er 28CT overcurrent protection
Er 29Return air temperature fault
Er 32Heating water outlet temperature too high protection
Er 33Outdoor coil high temperature protection
Er 42Internal coil temperature fault
Er 44Cooling environment temperature too low protection
Er 45Heating environment temperature too low protection

Troubleshooting

NO.FaultAnalysisSolution
E03Water flow protection1. Poor connection between water flow switch and main board. 2. Water flow switch installed incorrectly. 3. Water flow switch failure. 4. Main board failure. 5.1 Water system blocked. 5.2 Pump not suitable. 5.3 Pipe too small. 5.4 Flow switch stuck and cannot reset. 6.1 Valve not open. 6.2 Pump not working. 6.3 Pump failure.1. Reconnect switch cable. 2. Reinstall correctly. 3. Replace switch. 4. Replace main board. 5.1 Clean/replace blocked parts. 5.2 Install correct pump. 5.3 Replace pipe. 5.4 Reset switch manually. 6.1 Open valve. 6.2 Turn on pump. 6.3 Replace pump.
E04Anti-freeze protection1. Low ambient temperature. 2. Low water temperature.1. When ambient temp ≤ 8°C, exit anti-freeze. 2. When outlet water temp ≤ 15°C, exit anti-freeze.
E05High pressure protection1. Loose wiring/poor connection of switch. 2. Faulty high pressure switch. 3. Air in system. 4. Poor condensing. 4.1 Water temp too high (out of range). 4.2 Low water flow. 4.2.1 Valve not open. 4.2.2 Water system blockage/valve. 4.2.3 Improper pump. 4.2.4 Pump failure. 5. Refrigerant system blockage (throttle). 6. Air in refrigerant system (vacuum insufficient).1. Reconnect wiring. 2. Replace switch. 3. Replace main board. 4. Operate within range. 4.1 Open valve. 4.2 Clean/replace blockage. 4.3 Use water pump direct pump. 4.4 Replace pump. 5. Clean/replace blockage. 6. Vacuum and refill refrigerant.
E06Low pressure protection1. Loose wiring/poor connection of switch. 2. Faulty low-pressure switch. 3. Main board failure. 4. Refrigerant leak. 5. Expansion valve malfunction.1. Reconnect wiring. 2. Replace low-pressure switch. 3. Replace main board. 4. Find leak, vacuum, and refill refrigerant. 5. Repair or replace expansion valve.
E09 / E10Communication fault1. Poor connection between wire controller and main board. 2. Controller failure. 3. Main board failure. 4. Communication cable placed with power cable, causing interference.1. Reconnect controller cable. 2. Replace controller. 3. Replace main board. 4. Separate communication and power cables.
E12Exhaust protection1. Temperature sensor failure. 2. Water flow switch failure. 3. Water pump failure. 4. Low water flow. 4.1 Blocked system. 4.2 Pump not suitable. 4.3 Pipe too small. 4.4 System air block. 5. No water flow. 5.1 Valve not open. 5.2 Pump not working. 5.3 Pump failure.1. Replace temp sensor. 2. Replace water flow switch. 3. Repair leak and refill refrigerant. 4. Clean/replace blockage. 4.1 Replace with correct pump. 4.2 Replace pipe. 4.3 System air purge. 5. Open valve. 5.1 Turn on pump. 5.2 Replace pump.
E15 / E16 / E18 / E21 / E27 / E29 / E42Sensor faults (inlet water, external coil, exhaust pipe, ambient temp, outlet water, suction, internal coil)1. Poor connection between sensor and main board. 2. Sensor failure. 3. Sensor resistance failure on main board.1. Reconnect sensor cable. 2. Replace sensor. 3. Replace main board.
E19DC Fan failure1. Poor connection between fan and main board. 2. Fan failure.1. Check motor and wiring. 2. Replace fan.

Maintenance & Cleaning

Maintenance & Cleaning

Welcome to the Coldture Wellness Club

Person relaxing in a Pro Plunge Xtreme ice bath with mountain landscape in background

welcome to the coldture wellness club

coldture.com